Floor insulation
Contents |
[edit] Introduction
In the average home, approximately 10% of the heat loss is through the ground floor. Therefore, insulation as a means of reducing heat loss is typically installed on the ground floor. However, it may also be provided in upper-floors between heated and unheated areas. In comparison with wall insulation or roof insulation, savings associated with floor insulation are more modest, but under some circumstances, installation costs can be lower.
The installed performance of an insulation product is dependent on:
- The performance characteristics of the insulation material.
- The suitability of the insulant to its installed location.
- Adherence to manufacturer’s instructions.
- Quality of workmanship.
- Defects, gaps in insulation, thermal bridging and moisture penetration.
Commonly-used floor insulation materials include:
- Cellulose.
- Cork board.
- Hempcrete.
- Woodfibre.
- Mineral wool.
- Extruded Polystyrene (XPS).
- Expanded Polystyrene (EPS).
[edit] Building Regulations
Legislation such as the building begulations part L has acted as a catalyst for insulation, along with advanced voluntary programmes such as the Code for Sustainable Homes and BREEAM.
The building regulations require that floors achieve minimum thermal performance values (U-values – a measure of how quickly heat will travel through the floor), and this affects the amount of insulation required. For example, achieving a U-value of 0.25 W/m2K or less. would require at least 70 mm of high-performance foam insulation, or 150 mm of mineral wool, (although this will vary depending on floor type, construction, shape and size).
Calculations by Kingspan have produced best starting point values that are thought to be suitable for common situations.
[edit] U-values for floors in domestic buildings
England – April 2014
- New Build: Best starting point (fabric only) – 0.11
- Existing buildings: Extension – 0.22
- Existing buildings: Refurbishment – 0.25
Wales – 31st July 2014
- New Build: Best starting point (fabric only) – 0.15
- Existing buildings: Extension – 0.18
- Existing buildings: Refurbishment – 0.25
Scotland – 1st October 2015
- New Build: Best starting point (fabric only) – 0.13
- Existing buildings: Refurbishment and extensions (where existing dwelling’s walls and roof U-values are worse than 0.70W/m.K in the walls and worse than 0.25 W/m.K in the ceiling) – 0.15
- Existing buildings: Refurbishment and extensions (for other extensions, upgraded existing thermal elements, non-empty conservatories and conversion of unheated buildings) – 0.18
- Existing buildings: Conversion of heated buildings – 0.25
[edit] U-values for floors in non-domestic buildings
England – April 2014
- New Build: Best starting point (fabric only) – 0.18
- Existing buildings: Extension – 0.22
- Existing buildings: Refurbishment – 0.25
Wales – 31st July 2014
- New Build: Best starting point (fabric only) – 0.22
- Existing buildings: Extension – 0.18
- Existing buildings: Refurbishment – 0.25
Scotland – 1st October 2015
- New Build: Best starting point (fabric only) – 0.15
- Existing buildings: Refurbishment, extensions and conversion of unheated buildings – 0.20
- Existing buildings: Conversion of heated buildings – 0.25
NB See PA ratio for more information.
[edit] Insulation methods
[edit] New buildings
[edit] Insulation above the floor slab
Insulation is placed above the concrete slab, along with a separating/slip layer and then a rigid floor which is generally either screed or boarding. The damp proof membrane (DPM), which can be either above or below the slab, must be continuous with the damp proof course (DPC) in the surrounding walls. The insulation boards must be tightly butted and sealed to limit air leakage.
Heating response time is improved by having the insulation above the slab, and the insulation zone can be used to run services and underfloor heating. However, when used together with timber-based flooring it may be unsuitable for use in rooms that may get wet such as kitchens or bathrooms.
[edit] Insulation below the floor slab
Insulation is placed below the concrete floor slab. There are fewer restrictions on the thickness of the insulation in comparison with above slab insulation, and there is less of an issue with point loading as the load is spread over the slab rather than the insulation. However, rooms are slower to heat by comparison with above slab insulation.
[edit] Timber floor
The installation process follows the same method as that detailed below, although the process is easier as there is no existing flooring to remove or gain access to.
[edit] Retrofitting existing buildings
[edit] Simple draught-proofing
Sealant or caulking can be used to fill the gaps between floorboards and between skirting boards and the floor.
[edit] Timber floors
Older homes are more likely to have suspended timber floors (with no ceiling below). These can be insulated by raising the floorboards and laying mineral wool insulation supported by netting between the joists. This process is relatively easy if there is a cellar or an access hatch allowing entry to the crawlspace (void) below the floorboards. If not, the floorboards will need to be taken up. It is important to consider the propensity of timber floors for air leakage. Attention is needed when relaying old floorboards or installing new ones, to ensure that all joints between boards are adequately sealed.
[edit] Upgrading an existing concrete floor slab
Newer homes are far more likely to have a ground floor made of solid concrete. The simplest method of installation is to add insulation and a new floor deck on top of the existing floor. However, raising the floor level will usually require floor coverings skirtings, radiators and electrical fittings are removed and re-fitted, as well as reducing the heights of doors.
[edit] Related articles on Designing Buildings
- Approved Document L.
- Ash deafening.
- Beam and block.
- BREEAM.
- Cavity wall insulation.
- Code for Sustainable Homes.
- Crawl space.
- Domestic floors: Part 1: Construction, insulation and damp proofing.
- Fire insulation.
- Flooring.
- Flooring defects.
- Hatch.
- Heat transfer.
- How to fit carpet.
- Insulation for ground floors.
- PA ratio.
- Roof insulation.
- Solid wall insulation
- Sound insulation
- Thermal bridge
- Thermal insulation for buildings
- Transparent insulation.
- Types of carpet.
- Types of floor.
- Types of insulation.
- U-value
- Vapour barrier
Featured articles and news
CIOB launches global mental health survey
To address the silent mental health crisis in construction.
New categories in sustainability, health and safety, and emerging talent.
Key takeaways from the BSRIA Briefing 2024
Not just waiting for Net Zero, but driving it.
The ISO answer to what is a digital twin
Talking about digital twins in a more consistent manner.
Top tips and risks to look out for.
New Code of Practice for fire and escape door hardware
Published by GAI and DHF.
Retrofit of Buildings, a CIOB Technical Publication
Pertinent technical issues, retrofit measures and the roles involved.
New alliance will tackle skills shortage in greater Manchester
The pioneering Electrotechnical Training and Careers Alliance.
Drone data at the edge: three steps to better AI insights
Offering greater accuracy and quicker access to insights.
From fit-out to higher-risk buildings.
Heritage conservation in Calgary
The triple bottom line.
College of West Anglia apprentice wins SkillELECTRIC gold.
Scottish government launch delivery plan
To strengthen planning and tackle the housing emergency.
How people react in ways which tend to restore their comfort.
Comfort is a crucial missing piece of the puzzle.
ECA launches Recharging Electrical Skills Charter in Wales
Best solutions for the industry and electrical skills in Wales.
New homebuilding skills hub launch and industry response
Working with CITB and NHBC to launch fast track training.